Sanitizing draft beer installations at the point of sale
Published on February 8, 2023

Draft beer installations must be cleaned and disinfected at least every 14 days, while components that are alternately in contact with beer and air (for example, taps) need daily cleaning. Cleaning and disinfection must result in the lowest possible contamination level. To reliably achieve the required cleaning effect, the following requirements must be met:
- The design of the whole draft installation must allow easy sanitation and must not let product residues remain.
- All components must be built to sanitary requirements. This means avoiding weak points in the design where, for example, microorganisms can multiply freely and contaminate the beer.
What makes installation components dirty are strong adhesion forces acting between the soil deposits (beer compounds, microorganisms) and the surfaces of components and lines. Overcoming these forces with high liquid flow alone is not possible, which makes mechanical cleaning a viable solution.
In addition, capillary forces arise in gaps and corners and hold product residues in these problem spots, where they become a culture medium for microorganisms. The whole beer line circuit should be insulated, especially where it passes through warm areas (high temperatures speed up microbial growth).
Beer does not offer ideal conditions for microorganisms, because of its low pH and the presence of alcohol, CO2, hop components and lack of oxygen. At the end of service, the line circuit should be emptied and rinsed with water, keeping the lines full of water until the next service. In longer lines there will be a larger loss of beverage, but no harm to product quality.
The factors that influence the cleaning process are:
- Cleaning agent – the chemical activity of the cleaning solution – composition, concentration, surface tension, dispersing power, etc.; Time – the duration of the cleaning process – the longer the cleaning liquid circulates, the better the result. After a certain time, however, the additional effect is irrelevant.
- Mechanical action – the mechanical effect of the pumped cleaning solution, since a higher flow means better turbulence and mechanical removal of soil.
- Temperature – the temperature of the cleaning solution should suit the cleaning agent and the type of soil, allowing faster and deeper cleaning.
Not all factors need to stay constant during cleaning, and by adjusting individual factors we get an optimized cleaning procedure. Beer lines are usually cleaned with a single combined procedure (cleaning and disinfection), using a chlorinated alkaline product (3% concentration).
Lines can be cleaned mechanically using two sponge balls of the right size (7 and 10 mm), at a linear speed of 2 – 2.5 m/s. Without the sponges, the liquid's linear speed would have to be 4 – 7 m/s, which would create high pressures the installation (hoses, fittings, etc.) cannot withstand.
The basic cleaning procedure is:
- Pre-rinse with water;
- Circulation of 3% chlorinated alkaline solution, with two sponge balls;
- Rinse with water;
- Replacement of the sponge balls;
- Final rinse with water.
The effect of the final rinse can be improved when the water is not pumped in a continuous flow but intermittently or in pulses. The pulses help remove residues of cleaning and disinfection products from the pores of the installation. To remove beer stone (calcium oxalate), a suitable acid detergent can be used. Its compatibility with the various materials of the draft installation must be checked, however.
To keep draft beer quality at the point of sale, breweries and equipment manufacturers should share the goal of improving the (sanitary) design of installations and their components. Training and raising awareness among users of draft installations, together with periodic cleaning and disinfection, are enough to ensure the microbiological and organoleptic stability of the beer.
Authors:
Matthias R. Reinold – Certified Brewmaster (V.L.B – T.U. Berlin)